Fixed Gas Monitors
SENSING TECHNOLOGY
Detector Single Pass, Non-dispersive Infrared (NDIR)
GASES DETECTED
HGM - MZ R-11, R-12, R-22, R-23, R-113, R-114, R-123
R-124, R-134a,R-227, R236FA, R-401a, R-402a,
R125, R-402b, R-404a,R-407a, R407c,R-408a,
R409a, R-410a,R-500, R-502,R-503, R-507, R508b,
H-1211, H-1301, H-2404, N-1230
AGM-MZ Ammonia (NH
3
) - also known as R-717
CO
2
-MZ Carbon Dioxide (CO
2
) - also known as R-744
MEASUREMENT RANGE / RESOLUTION
All Refrigerants 0 -10,000 ppm in 1 ppm increments
Ammonia 25 -10,000 ppm in 1 ppm increments
Carbon Dioxide 0 - 8,000 ppm in 1 ppm increments
OUTPUTS
Relays Four SPDT alarm contacts are provided (rated 5
Amps at 250 volts). Three assigned to ppm level
alarms, one assigned to system fault
FRONT PANEL DISPLAY
3 Indicator Lights Green = Monitor is powered on. LED glows during
normal operation; flashes when unit is in warm-up
mode
Red = Alarm. LED flashes when any point has
exceeded the alarm setting
Yellow = Fault. LED flashes when there is a
system fault
COMMUNICATIONS
Full two-way communication with HGM-RD
Display Module or Building Management System
via RS-485 serial interface. RS-232C
communication port standard
OTHER SPECIFICATIONS
Power 100 to 240 VAC, 50/60 Hz. 20 W
Dimensions
12.23” H x 13.7” W x 4.96” D (78.9 cm x 88.39 cm x 40 cm)
Weight 15 lbs (6.80 kg)
Maximum Monitoring
Distance Up to 1,200 feet, from measuring point to monitor
Warranty 2 Years
CERTIFICATIONS
UL 61010-1, CSA 22.2 No. 61010-1
EN14624 & CE Mark
ORDERING INFORMATION
3015-5043 Halogen Gas Monitor 4 Zones
3015-5044 Halogen Gas Monitor 8 Zones
3015-5045 Halogen Gas Monitor 12 Zones
3015-5046 Halogen Gas Monitor 16 Zones
3015-5047 Ammonia Gas Monitor 4 Zones
3015-5048 Ammonia Gas Monitor 8 Zones
3015-5049 Ammonia Gas Monitor 12 Zones
3015-5050 Ammonia Gas Monitor 16 Zones
3015-5356 Carbon Dioxide Gas Monitor 4 Zones
3015-5357 Carbon Dioxide Gas Monitor 8 Zones
3015-5358 Carbon Dioxide Gas Monitor 12 Zones
3015-5359 Carbon Dioxide Gas Monitor 16 Zones
MULTI-ZONE KITS
3015-5330 Halogen Gas Monitor 4 Zones + Remote Display
3015-5331 Halogen Gas Monitor 8 Zones + Remote Display
3015-5332 Halogen Gas Monitor 12 Zones + Remote Display
3015-5333 Halogen Gas Monitor 16 Zones + Remote Display
3015-5334 Ammonia Gas Monitor 4 Zones + Remote Display
3015-5335 Ammonia Gas Monitor 8 Zones + Remote Display
3015-5336 Ammonia Gas Monitor 12 Zones + Remote Display
3015-5337 Ammonia Gas Monitor 16 Zones + Remote Display
3015-5338 Carbon Dioxide Gas Monitor 4 Zones + Remote Display
3015-5339 Carbon Dioxide Gas Monitor 8 Zones + Remote Display
3015-5340 Carbon Dioxide Gas Monitor 12 Zones + Remote Display
3015-5341 Carbon Dioxide Gas Monitor 16 Zones + Remote Display
ACCESSORIES
3015-5138 MZ-RD Remote Display (see page 34)
Multi-Zone Gas Leak Monitor (HGM-MZ / AGM-MZ / CO
2
-MZ
)
The Multi-Zone Gas Leak Monitor is a multiple area monitoring
system for low level continuous monitoring of refrigerant gases used
in most commercial systems including; CFC, HCFC, HFC, Ammonia
and Carbon Dioxide. This state-of-the-art product leads the industry
in performance, cost of ownership, integration capabilities and cost.
Capable of detecting more than 35 refrigerant gases, the system
design supports compliance to gas monitoring requirements of ANSI/
BSR ASHRAE 15-1994 and 15-2004, ETL Energy Saving Listed and
meets California Code Regulations for Refrigerant Monitors.
Bacharach’s HGM-MZ uses stable infrared detection technology,
and therefore requires only minor periodic maintenance such as the
occasional replacement of filters. The monitor incorporates active
diagnostics that continuously check the system for proper operation.
An audible alarm and front panel indicators are provided to signal
alarm and fault conditions, and relay contacts are provided that can
be used to trigger external alarm devices in the event of a system fault
or preset gas level thresholds.
• No costly calibrations required
• Fastest response time in the industry
Longest sampling distance of up to 1,200 feet
Rapid identification of alarm type, leak size
and location
Monitors up to 16 zones with a maximum of 64
zones in combination with 4 monitors controlled
by the Remote Display accessory unit
Full two-way communications via RS-485
*For Carbon Dioxide versions, call the factory for availability.
www.actoolsupply.com
www.actoolsupply.com