Bacharach H-10G Specifikace

Procházejte online nebo si stáhněte Specifikace pro Split-systém klimatizace Bacharach H-10G. Bacharach H-10G Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 20
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
H-10G
Refrigerant
Leak Detector
Congratulations! You have just
purchased the most versatile,
high performance service leak
detector available in the indus-
try today. It will detect refriger-
ants with a sensitivity that will
effectively pinpoint both small
and large leaks quickly and
efficiently. We encourage your
review of this manual to assure
satisfactory performance and a
long service life.
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - Leak Detector

H-10GRefrigerantLeak DetectorCongratulations! You have just purchased the most versatile, high performance service leak detector available in the indu

Strany 2 - Model Description

10Replacing the Sensor The sensor is a plug-in unit that can be discarded when expended. It needs replacing when the H-10G no longer responds to the

Strany 3 - Application

11Troubleshooting**Solution number corresponds to Cause number**Problem Responds continuously on small leak size positions. Balance control will not s

Strany 4 - Operating Instructions

12Troubleshooting (continued)**Solution number corresponds to Cause number**Problem No response to calibrate refer-enceCause 1Calibrate reference empt

Strany 5

13SpecificationsProduct Sensitivity (moving probe)(Movement not to exceed 2 in/sec, not greater than 0.25 inches from leak.) Switch Position LG MD

Strany 6

14Ordering Informaion3015-0456 H-10G Refrigerant Leak Detector (specify AC power requirements when ordering)3015-0326 14 inch Flexible Probe Extens

Strany 7 - Figure 3

15Repair InformationShould it become necessary to repair your H-10G, please contact an Authorized Service Center. Units should be carefully packed to

Strany 8 - Sensor Life Extension

16Authorized Service CentersUnited StatesBacharach Sales/Service Center621 Hunt Valley CircleNew Kensington, PA 15068Phone: 724-334-5051Fax: 724-334-5

Strany 12 - Troubleshooting (continued)

2Condensed Instructions1. Plug power cord into an appropriate AC outlet and let unit warm up for 2 minutes.2. Check flotation of airflow ball in probe

Strany 13 - Specifications

3015-0846REV. 8 - 9/2012621 Hunt Valley CircleNew Kensington, PA 15068Ph: 724-334-5000 • Fax: 724-334-5001 • Toll Free: 1-800-736-4666Website: http:/

Strany 14 - Ordering Informaion

3screwdriver adjustable sensor heat con-trol is located on the bottom of the unit. The probe nozzle consists of a trans-parent tip, airflow ball, fi

Strany 15 - Repair Information

4area may also occur where excessive amounts of refrigerants are vented. The H-10G cannot differentiate between atmospheric contamination and an actu

Strany 16 - Authorized Service Centers

5control unit chassisbalance controlleak sizeswitchsensorcoverprobe tipspeakercalibratereferencebottleflexiblehosepower cordpowerswitchFigure 1Caution

Strany 17

6Figure 26. Adjust the balance control (fig. 1) until the audio ticks slowly, about 1–3 ticks per second. The neon lamp in the probe (fig. 2 and fig.

Strany 18

7 The calibrate reference bottle may be used as often as necessary to assure proper operation of determin-ing the size of the leak. A leak that cau

Strany 19

8the tip at about one inch per second along seams or joints suspected of leaking. When the probe encoun-ters a leak, both the audio pitch and the flas

Strany 20 - New Kensington, PA 15068

9(fig. 4) and perform calibration. When making sensor adjustments, move the sensor heat control in small increments, either up or down, as appro-pri

Komentáře k této Příručce

Žádné komentáře