GA-40 T plus OPERATION
27
C - ZEROING the sensor
Connect end of the sample hose to the PRESSURE(+) stub. The screen will display the measured pressure
and the measured gas temperature.
À - leaves the option. The displayed value will be stored until a new one is stored or
either a printout of the measured values or of a protocol is performed.
5.5 Soot (smoke) Contents Measurement
To perform a soot test it is essential to prevent the flue gas from condensing on the filter. Therefore it is
necessary to use a heated probe holder. This is available as an option with the analyser. It is only possible to
perform a soot test if the instrument is connected to the mains.
The soot test is done by means of the Bacharach comparison method.
MENU - select the main MENU
 and à - move the cursor to SOOT TEST
Á - select the option, the pump is switched off and the following screen appears:
œ SOOT TEST 1/3
›
INSERT FILTER
ENTER – START
Insert the soot filter in the slit of the heated probe holder, and place the probe in the stack.
ENTER - starts the soot measurement. The pump is switched on and sucks in 60 s (according
to. TÜV) the required volume of 1.63 +/-0.07 l
œ SOOT TEST
32 sec
C - STOP
C - stops the soot test
After the soot test the filter is compared with a scale, and the evaluated soot number is entered.
Komentáře k této Příručce